[ IP Camera ] GV-BLFC5800 Automatically changes Relay Mode from Monostable to Bistable whenever VMS connects - 20250410

IP cameras related FAQs
sam
Posts: 1
Joined: April 15th, 2024, 10:24 am

[ IP Camera ] GV-BLFC5800 Automatically changes Relay Mode from Monostable to Bistable whenever VMS connects - 20250410

Unread post by sam »

Question:
The GV-BLFC5800 alarm output's relay mode automatically reverts to "Bistable" from "Monostable" when the GV-BLFC5800 connects to the GV-VMS.

When the IP camera's relay mode is set to "Monostable" in alarm output settings and connected to the GV-VMS, it automatically reverts to "Bistable".

IP camera’s alarm output setting before connected to GV-VMS:
Alarm Output Settings Before Connected to GV-VMS.jpg
Alarm Output Settings Before Connected to GV-VMS.jpg (72.39 KiB) Viewed 2465 times

IP camera’s alarm output setting after connected to GV-VMS:
Alarm Output Settings After Connected to GV-VMS.jpg
Alarm Output Settings After Connected to GV-VMS.jpg (65.15 KiB) Viewed 2465 times

Answer:
Only the 'Bistable' mode is supported in order to allow proper software control when IP camera’s connected to the GV-VMS.
Therefore, this is a specification and cannot be changed.

GV-BLFC5800 User's Manual:
https://s3.amazonaws.com/geovision_down ... Manual.pdf

In addition, the same rule also applies to IP cameras with I/O listed below:
NoModel
1GV-ABL2702
2GV-ABL4711
3GV-ABL4712
4GV-ABL8712
5GV-AVD2700
6GV-AVD4710
7GV-AVD8710
8GV-BLFC5800
9GV-EBD8711
10GV-FER5702
11GV-PTZ5810-IR
12GV-SD2322-IR
13GV-SD2722-IR
14GV-SD3732-IR
15GV-SD4825-IR
16GV-SD4834-IR
17GV-TBL4710
18GV-TBL4711
19GV-TBL4807
20GV-TBL4810
21GV-TBL8710
22GV-TBL8810
23GV-TDR2700
24GV-TDR4700
25GV-TDR4703
26GV-TDR4803
27GV-TDR8805
28GV-TFD4700
29GV-TFD4800
30GV-TMS20811
31GV-TMS8800
32GV-TVD4710
33GV-TVD4711
34GV-TVD4810
35GV-TVD4811
36GV-TVD8710
37GV-TVD8810

Reference:
[ C-20250409BD5001-L-0410 ] [VMS] RE: Automatically reverts Relay Mode from Monostable to Bistable whenever VMS connects.