[ LPR ] LPC2210 v1.01, out of focus, after reboot, object too close - 20180206

LPR Cameras, DSP-LPR, ASManager
Frank
Posts: 125
Joined: October 11th, 2016, 10:27 am

[ LPR ] LPC2210 v1.01, out of focus, after reboot, object too close - 20180206

Unread post by Frank »

Issue:
Out of focus after reboot in LPC2210 under the following condition 1) low light conditions or 2) power shortage while recognition target is within closed range.

Root cause:
LPC2210 is for long distance usage. Its lens' focal length is 9mm ~ 22mm, which converts to a distance between camera and object is 14 m ~ 21 m. In clients' case, the distance between LPC2210 and objects is within 10 m, which is out of our suggested range. That causes camera to lose its focus after reboot.

Solution:
Please upgrade the F/W to v1.04 or later.

Reference:
[ Polvision - 201711146002 ] Having GV-LPC2210 v1.03 2016-4-22, GV-LPC1200 v1.13 2017-9-19, GV-LPR1200 v1.13 2017-9-19 monitor dynamic scenes, it will lose its focus after reboot